elevator door sensor serve as a core safety mechanism for ensuring the safety of elevator passengers. Primarily relying on infrared beam sensing technology to provide intelligent anti-pinch protection, these sensors are widely deployed in various types of passenger elevators, offering comprehensive safety coverage for both people and objects entering or exiting the cabin. The core operational logic is both precise and highly sensitive, enabling continuous, round-the-clock monitoring of the elevator door's opening and closing zones to prevent safety incidents-such as doors pinching people or objects-at the source.
During the door-closing sequence, the light curtain sensor continuously emits multiple parallel infrared beams, creating a dense, three-dimensional protective detection grid. When the detection zone remains unobstructed, all infrared beams transmit smoothly to their corresponding receivers; with the sensor signal remaining intact and stable, the system automatically verifies that the doorway area is safe, thereby allowing the elevator doors to proceed with their normal closing operation.
Conversely, should a passenger, a body part, or a personal belonging enter or linger within the doorway-thereby interrupting even a single infrared beam-the corresponding receiver will instantly detect the signal interruption. The sensor immediately triggers an intelligent safety response mechanism, halting the closing motion and reversing the doors to open them again, thereby forcibly aborting the closing sequence. The doors will not resume their closing procedure until the obstruction has been completely removed from the detection zone and the infrared beam transmission has returned to normal; this entire process operates via intelligent sensing-automatically starting and stopping-without requiring any manual intervention.
Compared to traditional mechanical safety edges, elevator light curtain sensors offer distinct advantages: high detection precision, a wide sensing range, rapid response times, and the absence of mechanical wear. Their highly sensitive detection capabilities allow them to accurately identify even subtle obstructions, eliminating safety blind spots. Furthermore, their stable and durable performance effectively enhances the overall safety and reliability of elevator operations, maximizing the protection afforded to both passengers and their belongings; as such, they constitute an indispensable core safety component within modern elevator systems.

Example: WEC0-917 B 6 1- AC220
Power supply and output interface configuration:
AC220: 185V~290VAC, 50/60Hz control box, 1NO/1NC relay output
AC110: 110VAC±20%, 50/6OHz control box, 1NO/1NC relay output
DC24A: 15~30VDC control box, 1NO/1NC relay output
DC24B: 15~30VDC without control box, NPN transistor output, block output high level
DC24C: 15~30VDC without control box, NPN transistor output, block output low level
DC24D: 15~30VDC without control box, PNP transistor output, block output low level
DC24E: 15~30VDC without control box, PNP transistor output, block output high level
DC24F: 15~30VDC without control box, 1NC relay Electrical output
DC24G: 15~30VDC without control box, 1NO relay output
DC24R: 15~30VDC without control box, 1NC/1NO relay output
DC24S: 15~30VDC without control box, intelligent light curtain
Connecting cable:
1: 3.5m2, suitable for standard center-opening door elevator
2: 3.5m2, suitable for side-opening door elevator
3: 2.5m, 4.5m 1 each, suitable for new side-opening door elevator
4: 5m2, suitable for center-opening double-folding door elevator
Number of infrared transmitting/receiving tubes:
6: 17 pairs
4: 20 pairs
7: 32 pairs
5: 36 pairs
8: 40 pairs
9: 48 pairs
Profile appearance:
A
B
C
.
.
.
Z
WECO-917 series: WECO-917
WECO-957 series: WECO-957
WECO-987 series: WECO-987
|
Technical Parameters |
917 |
957 |
987 |
||||||||||
|
Technical Parameters |
|||||||||||||
|
Number of infrared tubes |
17pair |
32pair |
17pair |
20pair |
32pair |
36pair |
40pair |
48pair |
20pair |
38pair |
40pair |
48pair |
|
|
Response time |
Relay output |
66ms |
66ms |
65mg |
66ms |
6ms |
69ms |
73ms |
81ms |
665ms |
68ms |
73ms |
81ms |
|
Transistor output |
60ms |
60ms |
60m8 |
60ms |
60ms |
64ms |
68ms |
76ms |
60ms |
64ms |
68ms |
76ms |
|
|
Scanning beam |
94-33beam |
154-94beam |
94-33beam |
94-58beam |
154-94beam |
174-106beam |
194-118beam |
234-142beam |
94-58beam |
174-106beam |
194-118beam |
234-142beam |
|
|
Infrared tube spacing |
118mm |
50mm |
118mm |
84mm |
50mm |
48mm |
48mm |
40mm |
84mm |
48mm |
48mm |
40mm |
|
|
Minimum beam |
s20mm |
||||||||||||
|
Maximum beam |
≥1800mm |
≥1600mm |
≥1800mm |
≥1600mm |
≥1800mm |
≥1900mm |
≥1600mm |
≥1800mm |
≥1900mm |
||||
|
Complies with standards |
ENB1-70 |
EN81-20 Fixed installation) |
EN81-70 |
EN81-20 |
ENB1-20 EN81-70 |
EN81-20 Fixed installation |
EN81-20 |
EN81-20 EN81-70 |
|||||
|
Redundancy function |
o |
● |
O |
● |
O |
||||||||
|
(allows one transmitter to be blocked 120s after failure) |
Up and down direction: ±15mm7°, front and back direction ±3mm/5° |
||||||||||||
|
Position tolerance |
0-4000mm |
||||||||||||
|
Working distance |
-20°C-+65°C |
||||||||||||
|
reliability |
|||||||||||||
|
Anti-light interference ability |
100000Lux |
Can work normally in any sunlight environment |
|||||||||||
|
External protection etc. |
See product catalogue for details |
||||||||||||
|
Vibration test |
X, Y-Z three axes 2 hours each, amplitude 0.35mm, frequency 10-55Hz |
||||||||||||
|
Ring filling test high and low temperature) |
GB/T2423.1-GB/T2423.4 |
||||||||||||
|
Electromagnetic compatibility |
|||||||||||||
|
EN12015 EN12016 |
General circuit sales |
Safety circuit level |
|||||||||||
|
Function |
|||||||||||||
|
Indication function |
Receiver yellow Receiver red Power indicator light Status indicator
|
||||||||||||
|
Fault output function (Pedi fault output function control box) |
O |
● |
|||||||||||