Blue light Inverter + motherboard Lift Inverter Function
iBL6Elevator integrated controller
Model naming specifications
BL6-U O 4022

|
BL6 |
U |
0 |
4 |
022 |
|
|
Controller Series |
Controller Type |
Housing Structure |
Voltage level |
Maximum adaptable motor capacity |
Controller Type |
|
U: Integrated Elevator Controller |
C: Closed Type |
4:380V |
002:2.2KW |
None: Serial All-in-One Controller with or without a glass panel |
|
|
003:3.7KW |
|||||
|
005:5.5KW |
|||||
|
007:7.5KW |
W: With a metal panel |
||||
|
011:11KW |
B: Parallel All-in-One Controller |
||||
|
015:15KW |
C: Ultra-thin, caseless All-in-One Controller |
||||
|
018:18.5KW |
|||||
|
S: High-Performance Elevator-Specific Inverter |
0: Open Type |
2:220V |
S: Small All-in-One Controller |
||
|
022:22KW |
|||||
|
030:30KW |
H: Villa All-in-One Controller |
||||
|
037:37KW |
N: Molded Case All-in-One Controller |
||||
|
045:45KW |
M: Modular All-in-One Controller |
||||
|
055:55KW |
|||||
|
D: Single-Phase All-in-One Controller |
|||||
|
075:75KW |
M Series Integrated Controller Dimensions (400V Class)
|
Controller model |
Dimensions |
||
|
W |
H |
D |
|
|
BL6-U04005-NM |
222 |
348 |
200 |
|
BL6-U04007-NM |
|||
|
BL6-UO4011-NM |
|||
|
BL6-U04015-NM |
|||

|
Controller model |
Dimensions |
||
|
W |
H |
D |
|
|
BL6-U04018-M |
280 |
418 |
203 |
|
BL6-U04022-M |
|||
|
BL6-UO4030-M |
320 |
480 |
228 |
|
BL6-U04037-M |
441 |
650 |
324 |
|
BL6-U04045-M |
|||
|
BL6-U04055-M |
|||
|
BL6-U04075-M |
|||

The iBL6 integrated elevator controller is a next-generation intelligent elevator controller. It seamlessly integrates elevator logic control with variable-frequency drive control, offering advanced technology, superior performance, safety, reliability, and ease of use.
1. Advanced Technology
◎ Intelligent elevator logic control and high-performance variable-frequency drive control are seamlessly integrated, truly achieving integrated elevator control.
◎ Advanced vector control technology achieves precise motor decoupling, fully utilizing motor performance for enhanced elevator comfort.
◎ Utilizing advanced space vector PWM (Pulse Width Modulation) technology, it significantly improves power efficiency compared to traditional sinusoidal PWM methods, resulting in greater energy savings.
2. Superior Performance
◎ Intelligently generates optimal operating curves based on target floors, enabling direct landing and improving elevator efficiency.
◎ Utilizing CAN BUS serial communication technology, it delivers high-speed and reliable data transmission, simplifying system wiring and facilitating system expansion.
◎ An internet-based wireless remote monitoring system interface facilitates remote guidance, commissioning, maintenance, and monitoring of elevator operation.
3. Simple Commissioning
◎ Supports smart commissioning via mobile phone, providing comprehensive and clear guidance. It offers remote parameter fault transmission, online guidance, and balance coefficient detection, making on-site commissioning convenient and efficient.
◎ Easy self-learning of rotating or stationary motor parameters and initial motor angle.
◎ Fuzzy control with no-load compensation starting ensures excellent starting comfort, even without a weighing device.
◎ When configuring a Bluelight all-in-one device with a Bluelight Synchronous host, the built-in host model selection function can be used. This eliminates the need to enter motor parameters and perform parameter self-learning, greatly improving commissioning efficiency.
4. Safety and Reliability
◎ Advanced dual 32-bit CPUs + a programmable logic device (FPGA) provide complete elevator control, providing a "hardware" guarantee for safe and reliable elevator operation.
◎ Redundant design and comprehensive hardware and software protection ensure safe and reliable elevator operation.
◎ Professional EMC laboratory testing comprehensively improves electromagnetic interference resistance and internal electromagnetic disturbance suppression, adapting to the complexities of elevator sites.
◎ A monitoring function verifies the interruption of current flow from the controller to the host during each elevator stop.
|
Maximum adaptable motor power (KW) |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
twenty two |
30 |
37 |
45 |
55 |
75 |
||||||||||||||||||||
|
Rated output |
Rated output capacity ( KVA ) |
4.0 |
5.9 |
9 |
12 |
18 |
twenty two |
27 |
32 |
43 |
53 |
63 |
78 |
106 |
|||||||||||||||||||
|
Rated output current (A) |
5.5 |
9 |
14 |
18 |
27 |
34 |
41 |
48 |
65 |
80 |
96 |
128 |
165 |
||||||||||||||||||||
|
Maximum output voltage (V) |
Three-phase, AC 380 (corresponding to input voltage) |
||||||||||||||||||||||||||||||||
|
Rated frequency ( Hz ) |
50 |
||||||||||||||||||||||||||||||||
|
Maximum output frequency ( Hz ) |
120 |
||||||||||||||||||||||||||||||||
|
Input power |
Rated voltage (V) |
Three-phase, AC380 |
|||||||||||||||||||||||||||||||
|
Rated frequency ( Hz ) |
50 |
||||||||||||||||||||||||||||||||
|
Rated input current (A) |
10 |
12 |
17 |
twenty two |
32 |
41 |
49 |
58 |
78 |
96 |
115 |
147 |
190 |
||||||||||||||||||||
|
Allowable voltage fluctuations |
±15% |
||||||||||||||||||||||||||||||||
|
Allow frequency fluctuation |
±5% |
||||||||||||||||||||||||||||||||
|
Model BL6-U□20□□-□□ |
2002 |
2003 |
2005 |
2007 |
2011 |
2015 |
2018 |
2022 |
|||||||||||||||||||||||||
|
Maximum adaptable motor power (KW) |
2.2 |
3.7 |
5.5 |
7.5 |
11 |
15 |
18.5 |
twenty two |
|||||||||||||||||||||||||
|
Rated output |
Rated output capacity ( KVA ) |
4 |
7 |
10 |
14 |
20 |
27 |
33 |
40 |
||||||||||||||||||||||||
|
Rated output current (A) |
11 |
17 |
25 |
33 |
49 |
66 |
80 |
96 |
|||||||||||||||||||||||||
|
Maximum output voltage (V) |
Three-phase, AC 220 (corresponding to input voltage) |
||||||||||||||||||||||||||||||||
|
Rated frequency ( Hz ) |
50 |
||||||||||||||||||||||||||||||||
|
Maximum output frequency ( Hz ) |
120 |
||||||||||||||||||||||||||||||||
|
Input power |
Rated voltage (V) |
Three-phase, AC 220V; single-phase, AC 220V (power level 2.2 kW ~11 kW ) |
|||||||||||||||||||||||||||||||
|
Rated frequency ( Hz ) |
50 |
||||||||||||||||||||||||||||||||
|
Three-phase rated input current (A) |
15 |
twenty one |
27 40 52 |
68 |
92 110 |
||||||||||||||||||||||||||||
|
One-way rated input current (A) |
26 |
37 |
47 |
70 |
91 |
||||||||||||||||||||||||||||
|
Allowable voltage fluctuations |
+10%,-15% |
||||||||||||||||||||||||||||||||
|
Allow frequency fluctuation elevator |
±5% |
||||||||||||||||||||||||||||||||
|
The Common Parameters And Specifications Of The Entire Series Are As Follows |
|||||||||||||||||||||||||||||||||
|
Basic Features |
Control method |
Full selection control, two units in parallel, three to eight units group control |
|||||||||||||||||||||||||||||||
|
Elevator speed range |
0.5~4M/s |
||||||||||||||||||||||||||||||||
|
Applicable to the highest floor |
64th floor |
||||||||||||||||||||||||||||||||
|
Applicable ladder type |
Passenger elevators, residential elevators, ward elevators, sightseeing elevators, freight elevators |
||||||||||||||||||||||||||||||||
|
Applicable host |
Geared traction machine, gearless permanent magnet synchronous traction machine |
||||||||||||||||||||||||||||||||
|
Communication methods |
CAN bus serial communication |
||||||||||||||||||||||||||||||||
|
Leveling accuracy |
≤3mm |
||||||||||||||||||||||||||||||||
|
Drive control characteristics |
Control method |
Space Vector PWM ( SVPWM ) Closed-Loop Vector Control |
|||||||||||||||||||||||||||||||
|
Carrier frequency |
8 kHz (6~12 kHz adjustable) |
||||||||||||||||||||||||||||||||
|
Speed control range |
1:1000 |
||||||||||||||||||||||||||||||||
|
Speed control accuracy |
±0.05% (25℃±10℃) |
||||||||||||||||||||||||||||||||
|
Speed response |
30Hz |
||||||||||||||||||||||||||||||||
|
Torque limit |
Yes (set by parameters) |
||||||||||||||||||||||||||||||||
|
Torque accuracy |
±5% |
||||||||||||||||||||||||||||||||
|
Frequency control range |
0~120Hz |
||||||||||||||||||||||||||||||||
|
Frequency accuracy |
Digital setting: ±0.01% (-10℃+40℃) |
||||||||||||||||||||||||||||||||
|
Frequency setting resolution |
Digital setting: 0.01Hz |
||||||||||||||||||||||||||||||||
|
Output frequency resolution |
0.01Hz |
||||||||||||||||||||||||||||||||
|
Overload capacity |
150% rated current 60s; 180% rated current 10s |
||||||||||||||||||||||||||||||||
|
Starting torque |
180% rated current 0Hz |
||||||||||||||||||||||||||||||||
|
Acceleration and deceleration time |
0.001~600s |
||||||||||||||||||||||||||||||||
|
Main control functions |
No-load compensation start, battery operation, self-learning, load compensation, cooling fan control, base block, torque limit, CAN communication setting, acceleration and deceleration time, S curve acceleration and deceleration, host current flow effective blocking monitoring when parking, internal braking, PG frequency division output, fault automatic retry, fault automatic Reset, parameter copy |
||||||||||||||||||||||||||||||||
|
The Common Parameters And Specifications Of The Entire Series Are As Follows |
||
|
Control input and output interface |
Optocoupler input control power supply |
Isolated external DC24V |
|
Relay output control power supply |
Isolated internal DC24V |
|
|
Low voltage opto-isolated input |
26-way switching, rated load 7mA/DC24V, 100Hz online frequency |
|
|
High voltage optical isolation input |
4-way switch, rated load 8mA/AC110V, 100Hz online frequency |
|
|
Programmable relay output |
12-way switch 9-way: 1NO, contact capacity 5A/30VDC, 5A /250VAC 4-way: 1NO, contact capacity 8A/30VDC, 10A /250VAC |
|
|
CAN communication interface |
2-way, (parallel or group control, outbound call and operation panel and remote wireless monitoring) |
|
|
RS232 communication interface |
1 channel, digital operator, host computer monitoring, programming interface |
|
|
show |
Digital operator |
Chinese and English LCD display |
|
Monitoring software interface |
Menu, parameter value, status, variable timing, digital oscilloscope |
|
|
Main protection functions |
Instantaneous overcurrent protection |
Stop when the rated output current exceeds 200% |
|
Fuse blown protection |
Stop when fuse blows |
|
|
Overload protection |
Stop at 150% rated current for 60s or 180% rated current for 10s |
|
|
Overvoltage protection |
Stop when the DC bus voltage of the main circuit is higher than 720V (400V level) or 410V (200V level) |
|
|
Undervoltage protection |
stops when the DC bus voltage of the main circuit is lower than 380V (400V level) or 190V (200V level). |
|
|
Heat sink overheat protection |
Protected by thermistor |
|
|
IGBT module protection |
IGBT module overcurrent, overheating, short circuit, undervoltage protection |
|
|
Motor protection |
Overload protection stop |
|
|
Surge suppression circuit fault protection |
Protection via contactor feedback |
|
|
Overspeed protection |
Protection when exceeding the maximum allowable speed setting |
|
|
Out-of-tolerance protection |
Protection when speed deviation exceeds the allowable value |
|
|
PG fault protection |
Protection when PG is disconnected or phase mismatched |
|
|
Self-learning protection |
Motor self-learning abnormality protection |
|
|
Phase loss protection |
Input and output phase loss protection |
|
|
Door interlock failure |
Door interlock circuit disconnection protection during operation |
|
|
Emergency stop circuit failure |
Emergency stop circuit disconnection protection during operation |
|
|
Brake fault |
No gate opening feedback signal is received after the gate opening command is output |
|
|
Door zone signal failure |
Protection when door zone signal is abnormal |
|
|
Output contactor failure |
Output contactor abnormality protection |
|
|
Runtime protection |
Single running time exceeds the limit value protection |
|
|
Floor position counter failure |
Protection when floor position counter fails |
|
|
Communication interference failure |
Communication interference fault protection |
|
|
Well self-learning fault |
Protection when shaft self-learning fails |
|
|
structure |
Protection level |
With iron panel: IP20; without panel: IP00 |
|
Cooling method |
Forced cooling |
|
|
Installation |
Embedded or suspended installation in the cabinet |
|
|
Usage Environment |
Ambient temperature |
-10℃~+40°℃ |
|
Ambient humidity |
5~95%RH, no condensation |
|
|
Storage temperature |
-20℃~+60°℃ |
|
|
Place of use |
Indoors (no corrosive gas, flammable gas, dust and direct sunlight) |
|
|
Altitude |
Below 1000M |
|
|
vibration |
10~20Hz,<9.8m/S²;20~50Hz,<2m/S² |
|