Lift Inverter Function

Lift Inverter Function

The iBL6 integrated elevator controller is a next-generation intelligent elevator controller. It seamlessly integrates elevator logic control with variable-frequency drive control, offering advanced technology, superior performance, safety, reliability, and ease of use.
Send Inquiry
Description
Technical Parameters
Blue light Inverter + motherboard Lift Inverter Function

iBL6Elevator integrated controller

Model naming specifications
BL6-U O 4022

product-122-187

 

 

BL6

U

0

4

022

 

Controller Series

Controller Type

Housing Structure

Voltage level

Maximum adaptable motor capacity

Controller Type

 

U: Integrated Elevator

Controller

C: Closed Type

4:380V

002:2.2KW

None: Serial All-in-One Controller with or without a glass panel

003:3.7KW

005:5.5KW

007:7.5KW

W: With a metal panel

011:11KW

B: Parallel All-in-One Controller

015:15KW

C: Ultra-thin, caseless All-in-One Controller

018:18.5KW

S: High-Performance Elevator-Specific Inverter

0: Open Type

2:220V

S: Small All-in-One Controller

022:22KW

030:30KW

H: Villa All-in-One Controller

037:37KW

N: Molded Case All-in-One Controller

045:45KW

M: Modular All-in-One Controller

055:55KW

D: Single-Phase All-in-One Controller

075:75KW

 

M Series Integrated Controller Dimensions (400V Class)

 

Controller model

Dimensions

W

H

D

BL6-U04005-NM

222

348

200

BL6-U04007-NM

BL6-UO4011-NM

BL6-U04015-NM

product-157-215
 

Controller model

Dimensions

W

H

D

BL6-U04018-M

280

418

203

BL6-U04022-M

BL6-UO4030-M

320

480

228

BL6-U04037-M

441

650

324

BL6-U04045-M

BL6-U04055-M

BL6-U04075-M

product-136-196

 

The iBL6 integrated elevator controller is a next-generation intelligent elevator controller. It seamlessly integrates elevator logic control with variable-frequency drive control, offering advanced technology, superior performance, safety, reliability, and ease of use.

 

1. Advanced Technology
◎ Intelligent elevator logic control and high-performance variable-frequency drive control are seamlessly integrated, truly achieving integrated elevator control.
◎ Advanced vector control technology achieves precise motor decoupling, fully utilizing motor performance for enhanced elevator comfort.
◎ Utilizing advanced space vector PWM (Pulse Width Modulation) technology, it significantly improves power efficiency compared to traditional sinusoidal PWM methods, resulting in greater energy savings.

 

2. Superior Performance
◎ Intelligently generates optimal operating curves based on target floors, enabling direct landing and improving elevator efficiency.
◎ Utilizing CAN BUS serial communication technology, it delivers high-speed and reliable data transmission, simplifying system wiring and facilitating system expansion.
◎ An internet-based wireless remote monitoring system interface facilitates remote guidance, commissioning, maintenance, and monitoring of elevator operation.

 

3. Simple Commissioning
◎ Supports smart commissioning via mobile phone, providing comprehensive and clear guidance. It offers remote parameter fault transmission, online guidance, and balance coefficient detection, making on-site commissioning convenient and efficient.
◎ Easy self-learning of rotating or stationary motor parameters and initial motor angle.
◎ Fuzzy control with no-load compensation starting ensures excellent starting comfort, even without a weighing device.
◎ When configuring a Bluelight all-in-one device with a Bluelight Synchronous host, the built-in host model selection function can be used. This eliminates the need to enter motor parameters and perform parameter self-learning, greatly improving commissioning efficiency.

 

4. Safety and Reliability
◎ Advanced dual 32-bit CPUs + a programmable logic device (FPGA) provide complete elevator control, providing a "hardware" guarantee for safe and reliable elevator operation.
◎ Redundant design and comprehensive hardware and software protection ensure safe and reliable elevator operation.
◎ Professional EMC laboratory testing comprehensively improves electromagnetic interference resistance and internal electromagnetic disturbance suppression, adapting to the complexities of elevator sites.
◎ A monitoring function verifies the interruption of current flow from the controller to the host during each elevator stop.

 

Maximum adaptable motor power (KW)

2.2

3.7

5.5

7.5

11

15

18.5

twenty two

30

37

45

55

75

Rated output

Rated output capacity ( KVA )

4.0

5.9

9

12

18

twenty two

27

32

43

53

63

78

106

Rated output current (A)

5.5

9

14

18

27

34

41

48

65

80

96

128

165

Maximum output voltage (V)

Three-phase, AC 380 (corresponding to input voltage)

Rated frequency ( Hz )

50

Maximum output frequency ( Hz )

120

Input power

Rated voltage (V)

Three-phase, AC380

Rated frequency ( Hz )

50

Rated input current (A)

10

12

17

twenty two

32

41

49

58

78

96

115

147

190

Allowable voltage fluctuations

±15%

Allow frequency fluctuation

±5%

Model BL6-U□20□□-□□

2002

2003

2005

2007

2011

2015

2018

2022

Maximum adaptable motor power (KW)

2.2

3.7

5.5

7.5

11

15

18.5

twenty two

Rated output

Rated output capacity ( KVA )

4

7

10

14

20

27

33

40

Rated output current (A)

11

17

25

33

49

66

80

96

Maximum output voltage (V)

Three-phase, AC 220 (corresponding to input voltage)

Rated frequency ( Hz )

50

Maximum output frequency ( Hz )

120

Input power

Rated voltage (V)

Three-phase, AC 220V; single-phase, AC 220V (power level 2.2 kW ~11 kW )

Rated frequency ( Hz )

50

Three-phase rated input current (A)

15

twenty one

27 40 52

68

92 110

One-way rated input current (A)

26

37

47

70

91

   

Allowable voltage fluctuations

+10%,-15%

Allow frequency fluctuation elevator

±5%

The Common Parameters And Specifications Of The Entire Series Are As Follows

Basic Features

Control method

Full selection control, two units in parallel, three to eight units group control

Elevator speed range

0.5~4M/s

Applicable to the highest floor

64th floor

Applicable ladder type

Passenger elevators, residential elevators, ward elevators, sightseeing elevators, freight elevators

Applicable host

Geared traction machine, gearless permanent magnet synchronous traction machine

Communication methods

CAN bus serial communication

Leveling accuracy

≤3mm

Drive control characteristics

Control method

Space Vector PWM ( SVPWM ) Closed-Loop Vector Control

Carrier frequency

8 kHz (6~12 kHz adjustable)

Speed control range

1:1000

Speed control accuracy

±0.05% (25℃±10℃)

Speed response

30Hz

Torque limit

Yes (set by parameters)

Torque accuracy

±5%

Frequency control range

0~120Hz

Frequency accuracy

Digital setting: ±0.01% (-10℃+40℃)

Frequency setting resolution

Digital setting: 0.01Hz

Output frequency resolution

0.01Hz

Overload capacity

150% rated current 60s; 180% rated current 10s

Starting torque

180% rated current 0Hz

Acceleration and deceleration time

0.001~600s

Main control functions

No-load compensation start, battery operation, self-learning, load compensation, cooling fan control, base block, torque limit, CAN communication setting, acceleration and deceleration time, S curve acceleration and deceleration, host current flow effective blocking monitoring when parking, internal braking, PG frequency division output, fault automatic retry, fault automatic Reset, parameter copy

 

The Common Parameters And Specifications Of The Entire Series Are As Follows

Control input and output interface

Optocoupler input control power supply

Isolated external DC24V

Relay output control power supply

Isolated internal DC24V

Low voltage opto-isolated input

26-way switching, rated load 7mA/DC24V, 100Hz online frequency

High voltage optical isolation input

4-way switch, rated load 8mA/AC110V, 100Hz online frequency

Programmable relay output

12-way switch

9-way: 1NO, contact capacity 5A/30VDC, 5A /250VAC 4-way: 1NO, contact capacity 8A/30VDC, 10A /250VAC

CAN communication interface

2-way, (parallel or group control, outbound call and operation panel and remote wireless monitoring)

RS232 communication interface

1 channel, digital operator, host computer monitoring, programming interface

show

Digital operator

Chinese and English LCD display

Monitoring software interface

Menu, parameter value, status, variable timing, digital oscilloscope

Main protection functions

Instantaneous overcurrent protection

Stop when the rated output current exceeds 200%

Fuse blown protection

Stop when fuse blows

Overload protection

Stop at 150% rated current for 60s or 180% rated current for 10s

Overvoltage protection

Stop when the DC bus voltage of the main circuit is higher than 720V (400V level) or 410V (200V level)

Undervoltage protection

stops when the DC bus voltage of the main circuit is lower than 380V (400V level) or 190V (200V level).

Heat sink overheat protection

Protected by thermistor

IGBT module protection

IGBT module overcurrent, overheating, short circuit, undervoltage protection

Motor protection

Overload protection stop

Surge suppression circuit fault protection

Protection via contactor feedback

Overspeed protection

Protection when exceeding the maximum allowable speed setting

Out-of-tolerance protection

Protection when speed deviation exceeds the allowable value

PG fault protection

Protection when PG is disconnected or phase mismatched

Self-learning protection

Motor self-learning abnormality protection

Phase loss protection

Input and output phase loss protection

Door interlock failure

Door interlock circuit disconnection protection during operation

Emergency stop circuit failure

Emergency stop circuit disconnection protection during operation

Brake fault

No gate opening feedback signal is received after the gate opening command is output

Door zone signal failure

Protection when door zone signal is abnormal

Output contactor failure

Output contactor abnormality protection

Runtime protection

Single running time exceeds the limit value protection

Floor position counter failure

Protection when floor position counter fails

Communication interference failure

Communication interference fault protection

Well self-learning fault

Protection when shaft self-learning fails

structure

Protection level

With iron panel: IP20; without panel: IP00

Cooling method

Forced cooling

Installation

Embedded or suspended installation in the cabinet

Usage Environment

Ambient temperature

-10℃~+40°℃

Ambient humidity

5~95%RH, no condensation

Storage temperature

-20℃~+60°℃

Place of use

Indoors (no corrosive gas, flammable gas, dust and direct sunlight)

Altitude

Below 1000M

vibration

10~20Hz,<9.8m/S²;20~50Hz,<2m/S²

 

Hot Tags: lift inverter function, China lift inverter function manufacturers, suppliers, factory, 3 Phase Lift Inverter, Elevator Door Inverter, Elevator Inverter Function, Lift Inverter, Lift Inverter 3 Phase, Lift Inverter Function

Send Message