Elevator safety protection systems encompass both mechanical and electrical aspects. The mechanical component primarily includes the speed limiter, safety clamp, car buffer, and counterweight buffer. If the elevator's operating speed exceeds the rated range and the safety circuit is disconnected, the speed limiter and safety clamp provide overspeed protection, forcibly clamping the elevator car to the hoistway rails and re-isolating the safety circuit. The buffer provides protection against overshooting or undershooting.
The electrical protection component, distributed throughout the elevator's operation, includes overload protection, electrical overspeed protection, reverse run protection, light curtain protection, door overload protection, motor no-load protection, phase loss and phase mismatch protection, and door lock short-circuit protection. These functions collectively ensure safe elevator operation in all situations, safeguarding the lives and property of passengers.

The key components and operating principles of the elevator safety protection system are as follows:

Mechanical Safety Devices
★ Overspeed Governor-Safety Clamp Interlocking System: The overspeed governor monitors the car speed in real time. When the speed exceeds 115% of the rated value, a mechanical action is triggered, driving the safety clamp to clamp the guide rails and forcibly brake the car.
★ Buffer: A hydraulic or spring device at the bottom of the shaft absorbs the impact energy of a falling car or counterweight, preventing bottom-squatting or top-striking accidents.
★ Door Locking System: A mechanical locking hook ensures electrical contact closure (engagement depth ≥ 7mm) after the landing door/car door is closed, preventing the risk of the elevator running with the door open.
Electrical Safety Protection System
★ Door Interlocking Protection: The electrical contacts of the landing door and car door are connected in series. If either is not closed, the elevator cannot start.
★ Overload Protection: A weighing device detects the load. If overload occurs, the elevator will not start and an alarm will be triggered.
★ Terminal Overrun Protection: Forced Speed Shift Switch: A deceleration prompt is issued before the terminal. Limit switch: Cuts off the operating circuit when overrunning.
★ Ultimate limit switch: Ultimate protection, directly cuts off the main power supply.
Collaborative Working Mechanism
★ Dynamic Response Logic:
In the event of overspeed, the speed limiter prioritizes triggering the electrical brake; if this fails, the safety clamp mechanically intervenes.
After the terminal overruns, the system responds in a step-by-step manner: forced speed change, limit switch, and limit switch, with buffers providing a safety buffer.
★ Redundant Design: Mechanical and electrical interlocks (power is cut off if the door lock is not engaged) ensure that a single fault does not cause a system crash.
Auxiliary Safety Components
★ Anti-pinch device: The car door light curtain or safety touch panel automatically deploys when encountering resistance, preventing pinching injuries.
★ Emergency System:
Automatic leveling during power failure: The emergency power source drives the car to the nearest stop to release passengers.
Emergency communication and lighting: Provides a rescue channel in case of entrapment.
The elevator safety system implements a closed "failure-shutdown" loop through layered protection, ensuring passenger safety.

Maintenance of the elevator safety protection system must strictly adhere to periodic regulations and technical standards to ensure the reliable function of all core components. The maintenance process and key points are as follows:
Regular Framework Maintenance
Biweekly Maintenance
Cleaning: Remove dust from the guide rails and foreign objects in the door slots. Wipe the car interior and operating panel (corrosive cleaners are prohibited).
Lubrication: Lubricate the guide rails and bearings with standard lubricant, and use special grease for the door wheel sliders.
Basic Inspection: Test the emergency brake button and alarm function, and monitor for abnormal operating noise.
Monthly Maintenance
Mechanical Inspection: Measure the brake clearance (≤0.7mm) and lubricate it.
Check the traction rope tension (deviation ≤5%) and any broken wires.
Electrical Safety: Test the control cabinet insulation resistance (power circuit ≥0.5 megohms).
Verify the door lock engagement depth (≥7mm) and electrical contact reliability.
Quarterly/Semi-Annual Maintenance
• Linkage Test:
• Speed limiter-safety gear linkage test (brake acceleration ≤ 0.2 m/s²).
• Calibrate the overload protection device to prevent startup when overloaded.
• Environmental Maintenance: Clean out accumulated water and debris from the pit and inspect the buffer for corrosion.
Annual Comprehensive Inspection
• Replace excessively worn guide shoe liners (wear > 30%), aged door locks, and other vulnerable parts.
• Test the effectiveness of limit switches and check the terminal overrun protection level.
Maintenance Points for Key Safety Components
|
Components |
Maintenance Details |
|
Speed Limiter-Safety Gear |
Clean mechanical components and check wedge flexibility; verify electrical switch priority during linkage testing. |
|
Door System |
Adjust door leaf clearance (≤6mm) and clean light curtain sensors; ensure safety contact plate trigger force meets elasticity standards. |
|
Buffer |
Replenish hydraulic oil for hydraulic models and check spring deformation for spring models; remove surface rust and apply corrosion protection. |
|
Safety Circuit |
Test the emergency stop switch and limit switch for continuity in separate blocks; tighten loose contacts and install anti-interference modules. |
Operating Instructions and Precautions
Process Compliance
• Place warning signs/guardrails before maintenance and perform maintenance operations with a special equipment operator's license.
• Run the machine three times without load after maintenance to confirm there is no abnormal vibration, noise, or leveling error (≤ 5 mm).
Fault Response
In the event of a safety circuit interruption, prioritize checking for phase sequence errors, overspeed limiter malfunction, or thermal relay overload.
In the event of door lock failure or short circuit risk, immediately stop the elevator and report for repair.
Responsibility: Select a qualified maintenance provider, fully record maintenance data, and obtain mutual signatures.
Note: System maintenance must adhere to the principle of "prevention first, combined with repair and maintenance," mitigating the risk of failure through a layered protection mechanism.
Huzhou Kenai Elevator Technology Co., Ltd. : Your Professional Elevator Safety System Supplier in China
We focus on integrated elevator manufacturing. Our smart elevator business integrates leading domestic elevator component companies, brings together high-end technical talents, and is committed to achieving technological innovation and building China's leading elevator industry.
One-stop spare parts supply
Covering core elevator components, including traction machines, wire ropes, door operators, and safety devices, we offer a complete range of spare parts in one place, with ample inventory and fast delivery.
Extensive industry experience
Our team has over 20 years of experience in the elevator industry, familiar with various brand standards and technical requirements, and can provide professional solutions.
Rapid response delivery
We maintain a large inventory of popular models to shorten lead times, and support rapid delivery of standard parts and OEM customized production.
Strict quality control
From raw materials to finished products, we conduct comprehensive quality inspections, adhering to the principle of safety first. Every product undergoes rigorous testing to ensure stability and safety.

Elevator Safety System is a core protection system that prevents overspeed, uncontrolled movement, and accidental fall.
The system activates automatically when elevator speed exceeds the limit or abnormal movement is detected. It stops the car safely and protects passengers and equipment.
Specification
|
Product Name |
One-directional overspeed Governor |
Brand |
VKSFUJI |
|
Model Number |
OX-240 |
Specifications |
One-way mechanical |
|
Sheave diameter (mm) |
φ240 |
Wire rope (mm) |
φ6 φ8 |
|
Rated speed m/s |
≤1.75m/s |
Pulling force N |
≥500 |
|
Use |
Elevator speed limit |
Packing |
As customer required |
|
Payment |
T/T, L/C, other |
||
- Residential and commercial buildings
- High-rise construction projects
- Industrial freight elevators
- Public infrastructure projects
- Elevator upgrade and replacement markets

Customization Options
Rated Load Configuration
Safety gear and governor selected according to elevator load capacity.
01
Speed Matching
Overspeed governor calibrated based on elevator rated speed.
02
Guide Rail Compatibility
Designed to match different guide rail models.
03
Installation Structure Adjustment
Mounting dimensions adjusted according to elevator design drawings.
04
OEM Branding
Logo marking and custom packaging available. Supports distributor brand building.
05
Raw Material Verification
High-strength steel inspected before production.
Mechanical Performance Testing
Braking force testing and activation testing conducted before shipment.
Assembly Inspection
Critical components inspected to ensure accurate installation and performance consistency.
Final Safety Test
Each batch undergoes functional verification before packing.