Introduction
ARD – Automatic Rescue Device is an elevator emergency backup system, widely used in commercial, residential, and industrial buildings. During unexpected main power failures, It automatically drives the elevator car to the nearest landing and opens the doors so passengers can exit safely.
|
Product name |
Model Specifications |
Power KW |
Output Frequency |
Unit |
Quantity |
Remarks |
|
Power outage emergency leveling |
ARD/3P5.5E (12V/7AH*3) |
5.5(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P5.5E (12V/7AH*3) |
5.5(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P7.5E (12V/9AH*3) |
7.5(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P11E (12V/7AH*4) |
11(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P15E (12V/9AH*4) |
15(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P18.5E (12V/7AH*6) |
18.5(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P22E (12V/7AH*6) |
22(Three-phase) |
50/60HZ |
set |
1 |
380V |
|
Power outage emergency leveling |
ARD/3P30E (12V/9AH*6) |
30(Three-phase) |
50/60HZ |
set |
1 |
380V |
Features
Continuous Monitoring
24-Hour Intelligent monitoring of elevator status, ensuring immediate response when needed.
Fast Activation
Rapid automatic start upon power failure without manual input, shortening the rescue time.
Precision Control
Uses a 32-bit microprocessor for controlling rescue operations and signal processing with high accuracy.
Automatic Charging
Includes sealed lead-acid batteries with automatic charge management, which increases the battery life.

Customization
- Power Ratings: Selectable models to match the inverter power of the elevator drive (e.g., 5.5 kW to 30 kW).
- Battery Configuration: Different battery capacities (e.g., 12 V/7 Ah, 12 V/9 Ah) depending on required rescue duration.
- Rescue Time Settings: Adjustable rescue operation period (typically 3–15 min) to fit building height and elevator travel requirements.
- Installation & Integration: Tailored wiring and control interface options to integrate with existing elevator control systems.
|
Mains input |
Voltage |
Three phaes AC380V±15% |
|
Frequency |
50Hz/60Hz |
|
|
Inverter output |
Inverted output voltage |
Three phaes AC380V±10% |
|
Efficiency |
≥0.85 |
|
|
Output frequency |
50Hz/60Hz(Rated value 50Hz) |
|
|
Waveform |
Sine wave |
|
|
Bettery |
Type |
Valve-contr olled sealed lead-acid battery |
|
Rescue time |
3-15Min(adjustable) |
|
|
Charging time |
≥6Hours |
|
|
Environment |
Ambient temperature |
0℃-45℃ |
|
Relative humidity |
<90%(No dew) |
|
|
Noise |
≤45dB |
|
|
Altitude |
≤2000M |
|
Model |
MST-ARD-3P5.5E |
MST-ARD-3P7.5E |
MST-ARD-3P11E |
MST-ARD-3P15E |
MST-ARD-3P18.5E |
MST-ARD-3P22E |
MST-ARD-3P30E |
|
Applicable elevator inverter power |
5.5KW |
7.5KW |
11KW |
15KW |
18.5KW |
22KW |
30KW |
|
Battery specifications |
12V7AH |
12V/9AH |
12V7AH |
12V/9AH |
12V/9AH |
12V/7AH |
12V/9AH |
|
Oil specifications |
3 |
3 |
4 |
4 |
4 |
6 |
6 |
|
Weight (KG) |
21 |
21 |
23 |
26 |
26 |
45 |
47 |
|
Dimensions Length * Width * Height (mm) |
402*305*160 |
402*305*160 |
402*305*160 |
402*305*160 |
402*305*160 |
538*400*160 |
538*400*160 |

FAQ
Q1: Is the ARD compatible with all elevator brands?
A: Yes - models are designed with three-phase output adaptable to many common elevator systems; specification matching is recommended with technical documentation.
Q2: Does this unit require manual battery charging?
A: No - the device includes automatic battery charge management to maintain readiness without manual intervention.
Q3: Where is the ARD installed?
A: ARD is typically installed within the elevator machine room or electrical cabinet, connected to the control system and power supply.
Q4: What environmental conditions can it operate in?
A: Standard operating conditions include ambient temperatures 0–45 °C and relative humidity <90% without condensation.